Siemens Hicom 150
From Call Accounting Wiki
Categories: Siemens | Pbx
Siemens Hicom 150 Series
Informations from this page are valid for all models including: Hicom 150, Hicom 150 E (150E), Hicom 150 H OfficePoint, Hicom 150 H OfficePro, Hicom 150 H OfficeCom.
In OfficeCom OfficePoint, the V24/2 module provides two serial V.24 (RS-232) interfaces for connecting a PC, a printer, or Plus Products (such as Uniform Call Distribution). The V24/1 (not for U.S.) is an under equipped version with only one V.24 (RS-232) interface.
Interfaces: V24 Interfaces (S30807-Q6916-Xxxx) Note: We recommend setting up call detail recording central (CDRC) on interface X2 of OfficeCom and OfficePoint (software configuration required) if a V24/2 module is installed.
Use a shielded 9-pin cable as a connecting cable. The wires must be twisted and have a diameter of at least 0.5 mm (24 AWG). The integrated wire shielding must be soldered onto the connector and socket housing of both cable ends. Short-haul modems must be provided if the cable length exceeds 15 m (50 ft.).
Pin Assignment of the 9-Pin Socket and 25-pin Connector on the V.24 (RS-232) Cable for OfficePro 9-Pin Sub-D Socket 25-Pin Sub-D Connector Signal 1 8 DCD (Data Carrier Detect) 2 3 RxD (Receive Data) 3 2 TxD (Transmit Data) 4 20 DTR (Data Terminal Ready) 5 7 GND (Signal Ground) 6 6 DSR (Data Set Ready) 7 4 RTS (Request To Send) 8 5 CTS (Clear To Send) 9 22 RI (Ring Indicator)
Cable V24/1 (Not for U.S.) and V24/2
Connector Assignment V.24 (RS-232) Contact Assignments, OfficeCom and OfficePoint